Loading...
O-3815-4-21ORDINANCE NO. 3815-4-21 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ALLEN, COLLIN COUNTY, TEXAS, AMENDING THE ALLEN LAND DEVELOPMENT CODE ZONING REGULATIONS AND ZONING MAP, AS PREVIOUSLY AMENDED, BY AMENDING THE REGULATIONS RELATING TO THE USE AND DEVELOPMENT OF LOT 7, BLOCK G, BRAY CENTRAL ONE, LOCATED IN DISTRICT F OF PLANNED DEVELOPMENT "PD" NO. 108 OFFICE "0" AND ADOPTING A CONCEPT PLAN AND BUILDING ELEVATIONS; PROVIDING FOR A CONFLICTS RESOLUTION CLAUSE; PROVIDING FOR A SEVERABILITY CLAUSE; PROVIDING FOR A SAVINGS CLAUSE; PROVIDING FOR A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000) FOR EACH OFFENSE; AND PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, the Planning and Zoning Commission and the g overning body of the City of Allen, Texas, in compliance with the laws of the State of Texas and the Ordinances of the City of Allen, Texas , have given the requisite notices by publication and otherwi se, and after holding due hearings and affording a full and fair hearing to all the property owners generally and to all persons interested and situated in the affected area, and in the vicinity thereof, and in the exercise of its legislative discretion, the City Council has concluded that the Allen Land Development Code Zoning Regulations and Zoning Map of the City of Allen, Texas , as previously amended, should be further amended as follows . NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF ALLEN, COLLIN COUNTY, TEXAS, THAT: SECTION 1. The Allen Land Development Code Zoning Regulations and Zoning Map of the City of Allen, Texas, as amended, be further amended by amending as set forth in Section 2 of this Ordinance the regulations relating to the use and development of Lot 7 , Block G, Bray Central One, an addition to City of Allen, Collin County , Texas , according to the plat thereofrecorded in Cabinet Q, Slide 111, Plat Records , Collin County, Texas ("the Property") located in District F of Planned Development "PD" No. 108 Office "O." SECTION 2. The Property shall be developed and used only in accordance with the applicable provisions of the Allen Land Development Code, as amended ("ALDC") and District F of Planned Development "PD" No. 108 as set forth in Ordinance No . 3044-10-11 , a s amended ( collectively "the PD I 08 Ordinance"), except to the extent modified by the Development Regulations set forth below: A. CONCEPT PLAN: The Property shall be developed in general conformance with the Concept Plan attached hereto as Exhibit "A " and incorporated herein by reference (the "Concept Plan"). Minor modifications to streets and driveways that do not alter the general alignment s hown on the Concept Plan may be made at the time of Site Plan approval. B. SETBACKS: The Prope1ty shall be developed in compliance with the setbacks shown on the Concept Plan. C. BUILDING ELEVATIONS: The Property shall be developed in general conformance with the architectural style set forth on the Building Elevations attached hereto as Exhibit "B" and incorporated herein by reference. D. PERMITTED USES: In addition to the uses permitted within District F of Planned Development "PD " No . I 08: (1) Bloc k G, Lot 7A, as identified on the Concept Plan, may be developed and used as a Medical Office; and (2) Block G , Lot 7B , as identified on the Concept Plan, may be developed and used as a Convenience store with Fuel Sta tion. E. LANDSCAPE BUFFER: Installation of all landscaping and irrigat ion within the 20 -foot wide landscape buffer a long Exchange Parkway and Raintree C ircl e , including a sidewa lk not less than five feet (5 .0 ') in width as shown on the Concept Plan , shall be completed prior to issuance of a certificate of occupancy for any building constructed on Lot 7 A and/or Lot 7B , Block G , as shown on the Concept Plan. SECTION 3. To the extent of any irreconcilable conflict wit h the provisions of this Ordinance and other ordinances of the C it y of Allen governing the u se a nd development of th e Property and w hich are not expressly amended by this Ordinance, the provisions of this Ordinance shall be controlling . SECTION 4. Should any word, sentence, paragraph, subdivisio n, clause, phrase or section of this Ordinance, or of the Allen Land Development Code, as amended hereby , be adjudged or held to be void or unconstitutional , the same shall not affect the va lidi ty of the remaining portions of sa id Ordinance or the Allen Land Development Code, as amended hereby, which shall remain in full force and effect. SECTION 5. An offense committed before the effective date of this Ordinance is governed by prior law and the provisions of the Allen Land Development Code Zoning Regulations , as amended, in effect when the offense was committed and the former law is continued in effect for this purpose . SECTION 6. Any person, firm or corporation v iolating any of the provi sions or terms of this Ordinance sha ll be subject to th e same penalty as provided for in Al len Land Development Code Zoning Regulations as previously amended , and upon conviction shall be punished by a fine not to exceed the sum of Two Thousand Dollars ($2,000) for each offense . SECTION 7. This Ordinance shall take effect immediately from and after its passage and publication of the caption in accordance wit h the provisions of the Charter of the City of Allen, and it is accordingly so ordained. DULY PAS SED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF ALLEN, COLLIN COUNTY, TEXAS, ON TIDS THE 13m DAY OF APRIL 2021. Kenneth M. Fulk, Mayor APPROVED AS TO FORM: ATTEST : Peter G. Smith, Cit ~rney (k b l:3/3 1/202 1: 12 1059) Ordinance No. 3815-4-21, Page 2 CONCRETE CURB SAW-CUT LINE MONUMENT/PYLON SIGN LIGHT POLE WHEEL STOPS HANDICAP SIGN HANDICAP LOGO STRIPING BOLLARD FENCE FIRE HYDRANT RAMP FIRE LANE PARKING SPACES TRAFFIC ARROW DUMPSTER SITE LEGEND EXISTING LEGEND BUILDING LINE EASEMENT BOUNDARY HIGHBANK LINE PARKING STRIPE RET. WALL TELE. BOX CABLE BOX WATER METER GAS METER OHU OVERHEAD UTILITY LINE UTILITY POLE TRANS. BOX ELECTRIC BOX SAN. SEW. CO. IR. VALVE STORM DRAIN MH. SAN. SEW. MH. IRRIGATION VALVE WATER VALVE FIRE HYDRANT GUY WIRE ANCHOR LIGHT POLE GAS MARKER ELECTRIC MH. TELEPHONE MH 20'9'9'9'9'18'10.4'9' 26' 8' 15.2'12'R3 0 'R30'R54 ' 28' 2 4 '9'24'PROPOSED BLOCK G, LOT 7A 1.35 ACRES 58,907 S.F. LAND USE: VACANT FUTURE LAND USE: MEDICAL 53 24' F.A.U.D.E. 5' SIDEWALK 221' 114.5'80'73'5 7 . 1 '8'F. A . U . E . R30' PROPOSED RIGHT TURN LANE PROPOSED STRIPING 9'9'9' 9 8.5'63.3'33.2'114.5' 221.6' 23.7'92.9'114.5' 220.5'234.07'10'8 PROPOSED 20' x 10' MASONRY ENCLOSURES W/ 8' WALLS AND SOLID DOORS OPENING 120 DEGREES REFER TO ARCH. PLANS FOR DETAILS 3 25'24' 18'9'3 9'18'R30'20'3 10 24'R30'60'24' F.A.U.D.E.RELOCATED TRAFFIC SIGNAL LIGHT POLE RELOCATED TRAFFIC SIGNAL BOX 30' 20'225' STORAGE124' TRANSITION5 425' 818'20'R30'R30'R30' 5 3 4 N 29°38'30" W 442.10'S 70°10'16" W 116.91'ǻ=1°30'07" R=1335.22' L=35.00' CB=N20°34'30"W CD=35.00'S 70°10'32" W 104.50'ǻ=9°27'45" R=1439.72' L=237.77 ' CB=S24°33'19"E CD=237.50' S 29°17'11" E 252.34'S 74°22'10" E35.01'N 60°29'40" E 200.05'ǻ=1°26'46" R=420.00' L=10.60' CB=N61°13'03"E CD=10.60' UTILITY VAULT UTILITY VAULT LOT 6, BLOCK G BRAY CENTRAL ONE PREGARD LLC INST. NO. 20070713000965610, O.P.R.C.C.T. ZONING: PD-54-IT LAND USE: MEDICAL LOT 3R-3A, BLOCK G, BRAY CENTRAL ONE VOL. 2016, PG. 50, P.R.C.C.T. LAND USE: MEDICAL RAINTREE CIR. (80' RIGHT-OF-WAY)EXCHANGE PKWY.(VARIABLE WIDTH RIGHT-OF-WAY)TANADGUSIX CORPORATION, INST. NO. 20170928001300540, O.P.R.C.C.T. ZONING PD-108-O VARIABLE WIDTHWASTEWATER EASEMENTCAB. Q, PG. 111,P.R.C.C.T. (PLAT)BUILDING LINE, CAB. Q, PG. 111, P.R.C.C.T. (PLAT)24' FIRELANE, WATER, WASTEWATER, DRAINAGE AND MUTUAL ACCESS EASEMENT CAB. P, PG. 190, CAB. Q, PG. 111, P.R.C.C.T. (PLAT) 20' LANDSCAPE EASEMENT CAB. Q, PG. 111, P.R.C.C.T. (PLAT) 30' B.L. CAB. Q, PG. 111 P.R.C.C.T. (PLAT) ONCOR DELIVERY COMPANY EASEMENT VOL. 5632, PG. 3056, D.R.C.C.T. CAB. Q, PG. 111, P.R.C.C.T. (PLAT) 15' LANDSCAPE EASEMENT CAB. Q, PG. 111 P.R.C.C.T. (PLAT) 15' DRAINA G E E A S E M E N T CAB. P, PG. 1 9 0 , C A B . Q , P G . 1 1 1 P.R.C.C.T. (P L A T ) 15' WATER E A S E M E N T CAB. P, PG. 1 9 0 , C A B . Q , P G . 1 1 1 P.R.C.C.T. (P L A T ) 24' FIRELANE, WATER, WASTEWATER, DRAINAGE & MUTUAL ACCESS EASEMENT CAB. Q, PG. 111, (P.R.C.C.T.) (PLAT) 10' X 10' WATERLINE EASEMENT CAB INET Q, PAGE 111 P.R.C.C.T. (PLAT) 10' X 10' WATERLINE EASEMENT CABINET Q, PAGE 111 CAB.P.R.C.C.T. (PLAT) 10' X 12' WATERLINE EASEMENT CAB.Q, PG. 111, P.R.C.C.T. (PLAT) EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING LOT 3, BLOCK A THR ALLEN VOL. 5311, PAGE 3275 D.R.C.C.T. LAND USE: MEDICAL ZONING: PD-54 CC 24' FIRELANE, WATER, WASTEWATER, DRAINAGE & MUTUAL ACCESS EASEMENT CAB. Q, PG. 111, (P.R.C.C.T.) (PLAT) 24' FIRELANE, WATER, WASTEWATER, DRAINAGE & MUTUAL ACCESS EASEMENT CAB. Q, PG. 111, (P.R.C.C.T.) (PLAT) 10' LANDSCAPE EASEMENT EASEMENT CAB. Q, PG. 111 P.R.C.C.T. (PLAT) A AL C TRACT 5, 35.752 ACRESBOSSY BOOTS HOLDINGS LTDLAND USE: VACANTZONING: PD-108 MIX80'R.O.W.80'R.O.W.D.D.E. D.D.E. 147.7'10' D.D.E.6'15' x 15' E.E. 4. 5 '30'36'P.A.E. 9'9' 9' 9' 9' 2 0 ' 9'8'8' 196.47'55.87'520'20'8'MEDICAL / SURGERY - GENERAL OFFICE (10,456 S.F.) (114.5' x 80') 15' x 335' VISIBILITY TRIANGLE 23. 7 ' 258.4'22'2 220'20'2 4 ' R57'R5 4 'R54'FH FH FH 15' W.E. 15' W.E. P.A.E. P.A.E.85'85' 8' 8' ADA RAMPS W/TRUNCATED DOMES PER CITY STD. MATCH LINE SEE SHEET CP-2 MATCH LINE SEE SHEET CP-1 FH 15'5'N=7,093,476.0907 E=2,527,074.8247 N=7,093,433.7574 E=2,526,854.2298 N=7,093,912.2000 E=2,526,852.6877 D.D.E. D.D.E. 10'D.D.E. D.D.E. 10'D.D.E. 10' D.D.E. P.A.E. D. D . E . D.D.E. N=7,093,818.0028 E=2,526,635.5790 20'10'20'10'143.7'99.3'133.1'9 6 . 9 ' 114.2' DESIGN DRAWN DATE PROJECT SHEET #TX PE FIRM #11525DESCRIPTIONDATENO.T: 469.331.8566 F: 469.213.7145 E: info@triangle-engr.comW: triangle-engr.com O: 1784 W. McDermott Drive, Suite 110, Allen, TX 750131KP MLM 121-2001-15-202101/15/201ST PD AMENDMENT SUBMITTALCITY OF ALLENCOLLIN COUNTY, TEXAS905 EXCHANGE PKWY.BYKP202-12-20212ND PD AMENDMENT SUBMITTALKPVICINITY MAP N.T.S. N SITE Feet 0 30 60 CP-1PD AMENDMENT CONCEPT PLANEASEMENT/SETBACK LEGEND NOTES 1. "APPLICANT SHALL COMPLY WITH CITY ORDINANCE, CHAPTER 6, HEALTH AND ENVIRONMENT, ARTICLE III, SOLID WASTE; SECTION 6-51 TO 6-80." 2. “APPLICANT SHALL COMPLY WITH ALL IRRIGATION REGULATIONS IN V.T.C.A. ADMINISTRATIVE CODE TITLE 30, CHAPTER 344 RULES ESTABLISHED BY THE STATE OF TEXAS; AND REQUIREMENTS FOR IRRIGATION DESIGN AND WATER CONSERVATION SET IN THE ALLEN LAND DEVELOPMENT CODE SECTION 7.05.6, AND THE CITY OF ALLEN WATER CONSERVATION AND DROUGHT CONTINGENCY AND EMERGENCY RESPONSE PLAN.” "NO PROTECTED TREES ON SITE" GENERAL NOTES 1. ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH THE STANDARDS OF THE CITY OF ALLEN. 2. A PERMIT IS REQUIRED TO CUT A CITY STREET OR WORK WITHIN THE RIGHT-OF-WAY. THE PERMIT IS ISSUED BY THE PUBLIC WORKS DEPARTMENT. 3. THE LOCATION OF UNDERGROUND UTILITIES INDICATED ON THE PLANS IS TAKEN FROM PUBLIC RECORDS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAKE ARRANGEMENTS WITH THE OWNERS OF SUCH UNDERGROUND UTILITIES PRIOR TO WORKING IN THE AREA TO CONFIRM THEIR EXACT LOCATION AND TO DETERMINE WHETHER ANY ADDITIONAL UTILITIES OTHER THAN THOSE SHOWN ON THE PLANS MAY BE PRESENT. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL UNDERGROUND UTILITIES. IF EXISTING UNDERGROUND UTILITIES ARE DAMAGED, THE CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF REPAIRING THE UTILITY. 4. WHERE EXISTING UTILITIES OR SERVICE LINES ARE CUT, BROKEN OR DAMAGED, THE CONTRACTOR SHALL REPLACE OR REPAIR THE UTILITIES OR SERVICE LINES WITH THE SAME TYPE OF ORIGINAL MATERIAL AND CONSTRUCTION, OR BETTER, UNLESS OTHERWISE SHOWN OR NOTED ON THE PLANS, AT HIS OWN COST AND EXPENSE. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER AT ONCE OF ANY CONFLICTS IN GRADES AND ALIGNMENT. 5. ALL EXCAVATIONS, TRENCHING AND SHORING OPERATIONS SHALL COMPLY WITH THE REQUIREMENTS OF THE U. S. DEPARTMENT OF LABOR, OSHA, "CONST. SAFETY AND HEALTH REGULATIONS", VOL. 29, SUBPART P. PG. 128 - 137, AND ANY AMENDMENTS THERETO. 6. ADEQUATE MEASURES SHALL BE TAKEN TO PREVENT EROSION. IN THE EVENT THAT SIGNIFICANT EROSION OCCURS AS A RESULT OF CONSTRUCTION THE CONTRACTOR SHALL RESTORE THE ERODED AREA TO ORIGINAL CONDITION OR BETTER. 7. THE CONTRACTOR SHALL RESTORE ALL AREAS DISTURBED BY CONSTRUCTION TO ORIGINAL CONDITION OR BETTER. RESTORED AREAS INCLUDE, BUT ARE NOT LIMITED TO TRENCH BACKFILL, SIDE SLOPES, FENCES, CULVERT PIPES, DRAINAGE DITCHES, DRIVEWAYS, PRIVATE YARDS AND ROADWAYS. 8. ANY CHANGES NEEDED AFTER CONSTRUCTION PLANS HAVE BEEN RELEASED, SHALL BE APPROVED BY THE CITY ENGINEER. THESE CHANGES MUST BE RECEIVED IN WRITING FROM THE FROM THE DESIGN ENGINEER. THE DIRECTOR OF PUBLIC WORKS SHALL APPROVE ANY DEVIATIONS FROM STATE REGULATIONS. 9. THE CONTRACTOR SHALL PROVIDE "RED LINED" MARKED PRINTS TO THE ENGINEER PRIOR TO FINAL INSPECTION INDICATING ALL CONSTRUCTION WHICH DEVIATED FROM THE PLANS OR WAS CONSTRUCTED IN ADDITION TO THAT INDICATED ON THE PLANS. ENGINEER TRIANGLE ENGINEERING LLC 1784 W. McDERMOTT DRIVE, SUITE 110 ALLEN, TEXAS 75013 CONTACT: KARTAVYA PATEL, P.E. PHONE: 469-331-8566 PROJECT CONTACT LIST SURVEYOR A & W SURVEYORS, INC. 2220 GUS THOMASSON ROAD MESQUITE, TEXAS 75150 CONTACT: JOHN S. TURNER PHONE: 972-691-4975 DEVELOPER DAVID HICKS COMPANY 401 WOODLAKE DR ALLEN, TEXAS 75013 CONTACT: DAVID HICKS PHONE: 214-720-9977 ARCHITECT BOTI ARCHITECTURE 5214 W. VILLAGE PKWY, SUITE 201 ROGERS, AR. 72758 CONTACT: WILNER DUBON PHONE: 479-381-4856 OWNER BOSSY BOOTS HOLDINGS LTD 905 EXCHANGE PARKWAY ALLEN, TEXAS 75013 CONTACT: DAVID HICKS PHONE: 214-720-9977 BUILDING SETBACK B.S. LANDSCAPE AREA L.A. FIRE LANE, ACCESS,F.A.U.D.E. UTILITY & DRAINAGE EASEMENT U.D.E. ACCESS EASEMENT A.E. PEDESTRIAN ACCESS EASEMENT P.A.E. SANITARY SEWER EASEMENT S.S.E. WATER EASEMENT W.E. ELECTRICAL EASEMENT E.E. UTILITY EASEMENT U.E. DRAINAGE & DETENTION EASEMENT D.D.E. PD/PD AMENDMENT CONCEPT PLAN MEDICAL / SURGERY - GENERAL OFFICE AND C-STORE WITH FUEL SALES 2.535 ACRES (110,440 S.F.) LOT 7, BLOCK G, BRAY CENTRAL ONE CITY OF ALLEN, COLLIN COUNTY, TEXAS 75013 JANUARY 15th, 2021 BUILDING SETBACKS - LOT 7A REQUIRED PROPOSED FRONT 25' FRONT 30' SIDE 10' SIDE 10' REAR 0' REAR 0' LOT 7A - SITE DATA SUMMARY TABLE BLOCK G LOT 7 PROPOSED LOT 7A EXISTING ZONING PD-108-O PROPOSED ZONING PD-108-O PROPOSED USE LOT AREA (S.F.)58,907 LOT AREA (ACRES)1.35 REQUIRED BUILDING SETBACK 25' FRONT ALONG RAINTREE CIR. 10' SIDE & 0' REAR PROVIDED BUILDING SETBACK 25' FRONT, 10' SIDE & 0' REAR REQUIRED LANDSCAPE SETBACK 10' FRONT, 20' SIDE & 0' REAR PROVIDED LANDSCAPE SETBACK 10' FRONT, 20' SIDE & 0' REAR MAXIMUM BUILDING HEIGHT 1 STORY (26') FIRST FLOOR AREA (S.F.)10,456 LOT COVERAGE 17.75% FLOOR AREA RATIO (FAR)0.18 PARKING REQUIREMENTS 1 SPACE PER 250 S.F. FLOOR AREA PARKING REQUIRED 42 REGULAR PARKING PROVIDED 59 HANDICAP PARKING REQUIRED 2 HANDICAP PARKING PROVIDED 2 TOTAL PARKING PROVIDED 61 LANDSCAPE AREA REQUIRED 15% LANDSCAPE AREA PROVIDED 16,958 S.F. OR 51.00% LOT 7B - SITE DATA SUMMARY TABLE BLOCK G LOT 7 PROPOSED LOT 7B EXISTING ZONING PD-108-O PROPOSED ZONING PD-108-O (AMENDED) PROPOSED USE C-STORE WITH FUEL LOT AREA (S.F.)51,533 LOT AREA (ACRES)1.18 REQUIRED BUILDING SETBACK 100' FRONT ALONG EXCHANGE PKWY, 15' SIDE & 0' REAR PROVIDED BUILDING SETBACK 100' FRONT, 15' SIDE & 0' REAR REQUIRED LANDSCAPE SETBACK 20' FRONT, 20' SIDE & 0' REAR PROVIDED LANDSCAPE SETBACK 20' FRONT, 20' SIDE & 0' REAR MAXIMUM BUILDING HEIGHT 1 STORY (26') FIRST FLOOR AREA (S.F.)4,088 LOT COVERAGE 7.93% FLOOR AREA RATIO (FAR)0.08 PARKING REQUIREMENTS 1 SPACE PER 200 S.F. FLOOR AREA PARKING REQUIRED 21 REGULAR PARKING PROVIDED 19 HANDICAP PARKING REQUIRED 2 HANDICAP PARKING PROVIDED 2 TOTAL PARKING PROVIDED 21 LANDSCAPE AREA REQUIRED 15% LANDSCAPE AREA PROVIDED 16,743 S.F. OR 51.00% EXHIBIT "A" CONCEPT PLAN Ordinance No. 3815-4-21, Page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ƌĂǁŝŶŐƐĂŶĚ^ƉĞĐŝĨŝĐĂƚŝŽŶƐĂƐŝŶƐƚƌƵŵĞŶƚƐŽĨ ƐĞƌǀŝĐĞĂƌĞĂŶĚƐŚĂůůƌĞŵĂŝŶƚŚĞƉƌŽƉĞƌƚLJŽĨƚŚĞ ƌĐŚŝƚĞĐƚ͘dŚĞLJĂƌĞŶŽƚƚŽďĞƵƐĞĚŽŶŽƚŚĞƌ ƉƌŽũĞĐƚƐŽƌĞdžƚĞŶƐŝŽŶƐƚŽƚŚŝƐƉƌŽũĞĐƚĞdžĐĞƉƚďLJ ĂŐƌĞĞŵĞŶƚŝŶǁƌŝƚŝŶŐĂŶĚǁŝƚŚĂƉƉƌŽƉƌŝĂƚĞ ĐŽŵƉĞŶƐĂƚŝŽŶƚŽƚŚĞƌĐŚŝƚĞĐƚ͘ ŽŶƚƌĂĐƚŽƌŝƐƌĞƐƉŽŶƐŝďůĞĨŽƌĐŽŶĨŝƌŵŝŶŐĂŶĚ ĐŽƌƌĞůĂƚŝŶŐĚŝŵĞŶƐŝŽŶƐĂƚũŽďƐŝƚĞ͖ƚŚĞƌĐŚŝƚĞĐƚ ǁŝůůŶŽƚďĞƌĞƐƉŽŶƐŝďůĞĨŽƌĐŽŶƐƚƌƵĐƚŝŽŶŵĞĂŶƐ͕ ŵĞƚŚŽĚƐ͕ƚĞĐŚŶŝƋƵĞƐ͕ƐĞƋƵĞŶĐĞƐŽƌƉƌŽĐĞĚƵƌĞƐ͕ ŽƌĨŽƌƐĂĨĞƚLJƉƌĞĐĂƵƚŝŽŶƐĂŶĚƉƌŽŐƌĂŵƐŝŶ ĐŽŶŶĞĐƚŝŽŶǁŝƚŚƚŚĞƉƌŽũĞĐƚ͘ dŚĞƐĞĂůĂŶĚƐŝŐŶĂƚƵƌĞĂƉƉůLJŽŶůLJƚŽƚŚĞĚŽĐƵŵĞŶƚ ƚŽǁŚŝĐŚƚŚĞLJĂƌĞĂĨĨŝdžĞĚĂŶĚǁĞĞdžƉƌĞƐƐůLJĚŝƐĐůĂŝŵ ĂŶLJƌĞƐƉŽŶƐŝďŝůŝƚLJĨŽƌĂůůŽƚŚĞƌƉůĂŶƐ͕ƐƉĞĐŝĨŝĐĂƚŝŽŶƐ͕ ĞƐƚŝŵĂƚĞƐ͕ƌĞƉŽƌƚƐŽƌŽƚŚĞƌĚŽĐƵŵĞŶƚƐŽƌ ŝŶƐƚƌƵŵĞŶƚƐƌĞůĂƚŝŶŐƚŽŽƌŝŶƚĞŶĚĞĚƚŽďĞƵƐĞĚĨŽƌ ĂŶLJƉĂƌƚŽƌƉĂƌƚƐŽĨƚŚĞƉƌŽũĞĐƚ͘ ^,d͗ :Kη͗ d͗C-STORE W/FUEL STATION #41360y,E'WZ<tzΘZ/EdZ/Z>REVIEW BOARD BUILDING ELEVATIONSR0.02 ϬϮͬϬϱͬϮϬϮϭ WZKdK͗ϭϬͲϮϯͲϮϬϭϵ;ϮϬϭϵͲϬϮͿ ϮϬϬϵϬ ϬϮͬϬϱͬϮϬϮϭ>>E͕dyϳϱϬϭϯZϬ͘ϬϮ ϯͬϭϲΗсϭΖͲϬΗϭZs/tKZ>sd/KEͲ &ZKEd ZϬ͘ϬϮ ϯͬϭϲΗсϭΖͲϬΗϮZs/tKZ>sd/KEͲ >&d ZϬ͘ϬϮ ϯͬϭϲΗсϭΖͲϬΗϯZs/tKZ>sd/KEͲ ZZ ZϬ͘ϬϮ ϯͬϭϲΗсϭΖͲϬΗϰZs/tKZ>sd/KEͲ Z/',d (;7(5,250$7(5,$/66&+('8/( 127$//0$7(5,$/6,16&+('8/($5(86(' 12 0$7(5,$/ 0$18)$&785(5 &2/25 05 0(0%5$1(522),1*'852/$67 :+,7( & 0$3(6/80,6+$'(&$123<:,7+5($5 *877(5&211(&7,21 0$3(6 %521=(%$.('(1$0(/ 6 $/80,1806725()5217*/$=,1*.$:1((5 79* )& )8(/&$123<)$6&,$5(<12%21'($670$1:+,7(3< % %5,&.%(/'21 &%5 678 678&&2 0(5/(;3$,17('6:$(67+(7,& :+,7( 3 (;7(5,25+2//2:0(7$/'2256)5$0(6 6&833(56'2:1632876&$123,(6 &251,&(&23,1*63$5$3(7&$36(;7(5,25 %2//$5'6$1'75$6+(1&/2685(*$7(6 6+(5:,1:,//,$06 (1'85,1*%521=( 6: 67 %/8))6721(1(875$/*5$<6:,1( +,172) $35,&27 (/'25$'26721( /$3/$7$%8))6721( 65 67$1',1*6($0522),1*7%' % %(/'(1%5,&.& 6 (/'25$'26721( 1 678&&2$(67+(7,&:+,7( 3 6:(1'85,1*%521=( & %521=(%$.('(1$0(/ 05 0(0%5$1(522),1* 65 67$1',1*6($0522),1*5(9'$7('(6&5,37,21EXHIBIT "B" BUILDING ELEVATIONS Ordinance No. 3815-4-21, Page 4 72),1,6+)/225   )& 65 % 72),1,6+)/225   % 65 )& &8/785('&$67 6721(6,// 6,// &+,6(/('7$1 67),1,6+75$16,7,21 72),1,6+)/225  ),1,6+75$16,7,21     720 % 67 3 62/,'(1&/2685(*$7(*$35(),1,6+('0(7$/3$5$3(7 &$3 0(',80%521=( 3$,17,17(5,252) '80367(5(1&/2685( 720$7&+ % 72),1,6+)/225  ),1,6+75$16,7,21     720 % 67 *$35(),1,6+('0(7$/3$5$3(7 &$3 0(',80%521=( &8/785('&$67 6721(6,// 6,// &+,6(/('7$1 72),1,6+)/225  ),1,6+75$16,7,21     720 % 67 *$35(),1,6+('0(7$/3$5$3(7 &$3 0(',80%521=( &8/785('&$67 6721(6,// 6,// &+,6(/('7$1 1 2 7 )2 5 &2 1 67 5 8 &7 ,2 1 ƌĂǁŝŶŐƐĂŶĚ^ƉĞĐŝĨŝĐĂƚŝŽŶƐĂƐŝŶƐƚƌƵŵĞŶƚƐŽĨ ƐĞƌǀŝĐĞĂƌĞĂŶĚƐŚĂůůƌĞŵĂŝŶƚŚĞƉƌŽƉĞƌƚLJŽĨƚŚĞ ƌĐŚŝƚĞĐƚ͘dŚĞLJĂƌĞŶŽƚƚŽďĞƵƐĞĚŽŶŽƚŚĞƌ ƉƌŽũĞĐƚƐŽƌĞdžƚĞŶƐŝŽŶƐƚŽƚŚŝƐƉƌŽũĞĐƚĞdžĐĞƉƚďLJ ĂŐƌĞĞŵĞŶƚŝŶǁƌŝƚŝŶŐĂŶĚǁŝƚŚĂƉƉƌŽƉƌŝĂƚĞ ĐŽŵƉĞŶƐĂƚŝŽŶƚŽƚŚĞƌĐŚŝƚĞĐƚ͘ ŽŶƚƌĂĐƚŽƌŝƐƌĞƐƉŽŶƐŝďůĞĨŽƌĐŽŶĨŝƌŵŝŶŐĂŶĚ ĐŽƌƌĞůĂƚŝŶŐĚŝŵĞŶƐŝŽŶƐĂƚũŽďƐŝƚĞ͖ƚŚĞƌĐŚŝƚĞĐƚ ǁŝůůŶŽƚďĞƌĞƐƉŽŶƐŝďůĞĨŽƌĐŽŶƐƚƌƵĐƚŝŽŶŵĞĂŶƐ͕ ŵĞƚŚŽĚƐ͕ƚĞĐŚŶŝƋƵĞƐ͕ƐĞƋƵĞŶĐĞƐŽƌƉƌŽĐĞĚƵƌĞƐ͕ ŽƌĨŽƌƐĂĨĞƚLJƉƌĞĐĂƵƚŝŽŶƐĂŶĚƉƌŽŐƌĂŵƐŝŶ ĐŽŶŶĞĐƚŝŽŶǁŝƚŚƚŚĞƉƌŽũĞĐƚ͘ dŚĞƐĞĂůĂŶĚƐŝŐŶĂƚƵƌĞĂƉƉůLJŽŶůLJƚŽƚŚĞĚŽĐƵŵĞŶƚ ƚŽǁŚŝĐŚƚŚĞLJĂƌĞĂĨĨŝdžĞĚĂŶĚǁĞĞdžƉƌĞƐƐůLJĚŝƐĐůĂŝŵ ĂŶLJƌĞƐƉŽŶƐŝďŝůŝƚLJĨŽƌĂůůŽƚŚĞƌƉůĂŶƐ͕ƐƉĞĐŝĨŝĐĂƚŝŽŶƐ͕ ĞƐƚŝŵĂƚĞƐ͕ƌĞƉŽƌƚƐŽƌŽƚŚĞƌĚŽĐƵŵĞŶƚƐŽƌ ŝŶƐƚƌƵŵĞŶƚƐƌĞůĂƚŝŶŐƚŽŽƌŝŶƚĞŶĚĞĚƚŽďĞƵƐĞĚĨŽƌ ĂŶLJƉĂƌƚŽƌƉĂƌƚƐŽĨƚŚĞƉƌŽũĞĐƚ͘ ^,d͗ :Kη͗ d͗C-STORE W/FUEL STATION #41360y,E'WZ<tzΘZ/EdZ/Z>REVIEW BOARD ELEVATIONSR0.03 ϬϮͬϬϱͬϮϬϮϭ WZKdK͗ϭϬͲϮϯͲϮϬϭϵ;ϮϬϭϵͲϬϮͿ ϮϬϬϵϬ ϬϮͬϬϱͬϮϬϮϭ>>E͕dyϳϱϬϭϯZϬ͘Ϭϯ ϯͬϭϲΗсϭΖͲϬΗϭ&h>^dd/KE>sd/KEͲ &ZKEd ZϬ͘Ϭϯ ϯͬϭϲΗсϭΖͲϬΗϮ&h>EKWz>sd/KEͲ ^/ ZϬ͘Ϭϯ ϯͬϭϲΗсϭΖͲϬΗϯhDW^dZE>K^hZͲ &ZKEd ZϬ͘Ϭϯ ϯͬϭϲΗсϭΖͲϬΗϰhDW^dZE>K^hZͲ ^/ ZϬ͘Ϭϯ ϯͬϭϲΗсϭΖͲϬΗϱhDW^dZE>K^hZͲ ZZ (;7(5,250$7(5,$/66&+('8/( 127$//0$7(5,$/6,16&+('8/($5(86(' 12 0$7(5,$/ 0$18)$&785(5 &2/25 05 0(0%5$1(522),1*'852/$67 :+,7( & 0$3(6/80,6+$'(&$123<:,7+5($5 *877(5&211(&7,21 0$3(6 %521=(%$.('(1$0(/ 6 $/80,1806725()5217*/$=,1*.$:1((5 79* )& )8(/&$123<)$6&,$5(<12%21'($670$1:+,7(3< % %5,&.%(/'21 &%5 678 678&&2 0(5/(;3$,17('6:$(67+(7,& :+,7( 3 (;7(5,25+2//2:0(7$/'2256)5$0(6 6&833(56'2:1632876&$123,(6 &251,&(&23,1*63$5$3(7&$36(;7(5,25 %2//$5'6$1'75$6+(1&/2685(*$7(6 6+(5:,1:,//,$06 (1'85,1*%521=( 6: 67 %/8))6721(1(875$/*5$<6:,1( +,172) $35,&27 (/'25$'26721( /$3/$7$%8))6721( 65 67$1',1*6($0522),1*7%'5(9'$7('(6&5,37,21 % %(/'(1%5,&.& 6 (/'25$'26721( 1 678&&2$(67+(7,&:+,7( 3 6:(1'85,1*%521=( & %521=(%$.('(1$0(/ 05 0(0%5$1(522),1* 65 67$1',1*6($0522),1* EXHIBIT "B" BUILDING ELEVATIONS (cont.) Ordinance No. 3815-4-21, Page 5 CONCEPT MEDICAL OFFICE BUILDING ELEVATIONS EXHIBIT "B" BUILDING ELEVATIONS (cont.) Ordinance No. 3815-4-21, Page 6