Loading...
O-3676-6-19 ORDINANCE NO.3676-6-19 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ALLEN, COLLIN COUNTY, TEXAS, AMENDING THE ALLEN LAND DEVELOPMENT CODE AND ZONING MAP, AS PREVIOUSLY AMENDED, BY AMENDING ORDINANCE NO.3452-2-17 GRANTING SPECIFIC USE PERMIT NO. 152 TO EXPAND THE PORTION OF THE BUILDING LOCATED ON LOT 1,BLOCK A,ALLEN BUSINESS CENTER II (ALSO KNOWN AS 718 S. GREENVILLE AVENUE, SUITE 150) WHICH MAY BE USED FOR A GYMNASTICS AND SPORTS TRAINING FACILITY USE IN AN APPROXIMATELY 20,866± SQUARE FOOT PORTION OF THE BUILDING; PROVIDING A CONFLICTS RESOLUTION CLAUSE; PROVIDING A SEVERABILITY CLAUSE; PROVIDING A SAVINGS CLAUSE; PROVIDING A PENALTY OF FINE NOT TO EXCEED THE SUM OF TWO THOUSAND DOLLARS ($2,000)FOR EACH OFFENSE;AND PROVIDING AN EFFECTIVE DATE. WHEREAS, the Planning and Zoning Commission and the governing body of the City of Allen, Texas, in compliance with the laws of the State of Texas and the ordinances of the City of Allen, Texas, have given the requisite notices by publication and otherwise,and after holding due hearings and affording a full and fair hearing to all the property owners generally and to all persons interested and situated in the affected area,and in the vicinity thereof,and in the exercise of its legislative discretion,have concluded that Allen Land Development Code Zoning Regulations and Zoning Map of the City of Allen,Texas,as previously amended,should be amended. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF ALLEN, COLLIN COUNTY,TEXAS,THAT: SECTION 1. The Allen Land Development Code Zoning Regulations and Zoning Map of the City of Allen, Collin County, Texas, shall be amended by amending Ordinance No. 3452-2-17, which originally authorized Specific Use Permit No. 152,as follows: A. Section 1 is amended as follows: (1) The phrase"13,095 square foot portion"shall be changed to read"20,866 square foot portion." (2) The address "718 S. Greenville Avenue" shall be changed to read "718 S. Greenville Avenue, Suite 150." B. Exhibit"A"of Ordinance No. 3452-2-17 is amended in its entirety to read as set forth in Exhibit"A-1" attached to this Ordinance and incorporated herein by reference(the"SUP Site Plan"). C. Exhibit `B"of Ordinance No. 3452-2-17 is amended in its entirety to read as set forth in Exhibit`B-1" attached to this Ordinance and incorporated herein by reference(the"Amended Parking Study"). SECTION 2. The Property,as defined in Ordinance No. 3452-2-17 and as amended by this Ordinance, shall be subject to the development and use regulations of Specific Use Permit No. 152 as originally granted by Ordinance No. 3452-2-17, it being the express intent of the City Council to merely expand the area of the Property encompassed within Specific Use Permit No. 152 without further amendment to Section 2 of Ordinance No. 3452-2-17. SECTION 3. To the extent of any irreconcilable conflict with the provisions of this ordinance and other ordinances of the City of Allen governing the use and development of the Property and which are not expressly amended by this ordinance,the provisions of this ordinance shall be controlling. SECTION 4. Should any word,sentence,paragraph,subdivision,clause,phrase or section of this ordinance,or of the Allen Land Development Code Zoning Regulations, as amended hereby,be adjudged or held to be void or unconstitutional,the same shall not affect the validity of the remaining portions of said ordinance or the Allen Land Development Code Zoning Regulations,as amended hereby,which shall remain in full force and effect. SECTION 5. An offense committed before the effective date of this ordinance is governed by prior law and the provisions of the Allen Land Development Code Zoning Regulations,as amended,in effect when the offense was committed,and the former law is continued in effect for this purpose. SECTION 6. Any person,firm or corporation violating any of the provisions or terms of this ordinance shall be subject to the same penalty as provided for in Allen Land Development Code Zoning Regulations of the City of Allen, as previously amended, and upon conviction shall be punished by a fine not to exceed the sum of Two Thousand Dollars($2,000)for each offense. SECTION 7. This ordinance shall take effect immediately from and after its passage and publication in accordance with the provisions of the Charter of the City of Allen,and it is accordingly so ordained. DULY PASSED AND APPROVED BY THE CITY COUNCIL OF THE CITY OF ALLEN, COLLIN COUNTY,TEXAS,ON THIS 11TH DAY OF JUNE 2019. APPROVED: twc�)—Ica Steph Terrell,MAYOR APPROVED AS TO FORM: ATTEST: Peter G.Smith,CiTY ATTORNEY She ey B.Geo ,TRMC,CITY SECRETARY (kbl:5/31/19:108432) Ordinance No. 3676-6-19, Page 2 TECH CENTER ONE at E-1"q THE TECH CENTER on GREENVILLE \ a^ tonin¢PO 3 Ligte Industrial o � Lot Size, 2.896 Ac(117,420 sf) 1k rf wav BUM"Area 37.127 SF -�S:` '��` \ •\ ' Lot Coverage 31B% �', ' l FAR 0.318.1 ..4S �'� ���6'6\p:. Suodi g H.gtn 2T-one story �e.q•A7yg; �'4"ki'4t w'�'., 'J` Parking Req'd 72 Parking ProVd ACCesatola Perking Provided As Par TAS ml-ements 110011111111 1,4 SUP REQUEST FOR 0 ALLIANCE CHEER LLC EXPANSION aUse.Gymnastics and Sports Training Faulty Tenant Space 2O.666 SF Parking Raao Vanes.see par"analysis Pa p rking Req'd par Code.123 Parking Req'a per Actual Usage 52 PeAmg Prov d(Pro-ratal. 67 41l O Guidelines for parking.cirpaatmn and picwptarop-0U unit pe provided by Tenant to tr r Clients upon enrollment and \-\ /f �`�Y ✓ '1*e f ;:, /�•-� enforced M Tenant as Van of normal operations71 . �,ro SUP SITE PLAN,-----.,, \ rIl N.NMN.ReM 9W[a IIJ . -. 4!Sm1ESr. w>.NMn.WAq 2DN N,YN•eatl.5va n0 .gf•N.r' Sir„¢r, EXHIBIT"B-1" AMENDED PARKING STUDY February 7, 2017 PK NO:1829-13.144 PARKING DEMAND ANALYSIS Alliance Cheer at Tech Center One In Allen, Texas Preu-,_,,r City of Allen GreenTech One LP CJtPr( l i C�le�p� 2/7/17 Pacheco Koch 7557 Rambler Road,Suite 1400 Dallas,Texas 75231-2388 (972) 235-3031 www.pkce.com TX.REG:ENGINEERING FIRM F-14439 TX.REG.SURVEYING FIRM LS-10193805-00 Ordinance No. 3676-6-19, Page 4 EXHMIT"B-1" AMENDED PARKING STUDY cont. A Pacheco Koch February 7,2017 TABLE OF CONTENTS INTRODUCTION.._...... . . _........._... .. _.............._............................. ........_ . . .. ..........1 Purpose............. .............................. _ ...................... .... ...................... .... ..................... 1 ProjectDescription...................................................................................................................... 1 CodeParking Requirement..........................................................................................................2 PARKING DEMAND ANALYSIS..........................................................................................3 Office ShowroonyWarehouse.......................................................................................................3 Cheerleading/Tumbling Athletic Facility........................................................................................3 ProjectedSite Parking Demand...................................................................................................4 SUMMARY OF FINDINGS..................... __......................_................. . .......... .... . _5 LIST OF TABLES: Table 1. Development Program Summary Table 2. Base Code Parking Requirement LIST OF EXHIBITS: Exhibit 1. Hourly Profile-Office Showroom/Warehouse Use Exhibit 2. Hourly Profile-Cheer/Tumbling Facility Exhibit 3. Project Hourly Profile-Tech Center One APPENDIX Parking Demand Analysis Alliance Cheer at Tech Center One Page Ordinance No. 3676-6-19, Parc 5 EXHIBIT`B-1" AMENDED PARKING STUDY cont. A Pacheco Koch February 7,2017 INTRODUCTION The services of Pacheco Koch(PK)were retained by GreenTech One LP,to conduct a Parking Demand Analysis (PDA) for the proposed Alliance Cheer(tenant)within the development known as Tech Center One (the "Project") located at 718 S. Greenville Avenue in Allen,Texas. A proposed site plan (provided by the Owner) is provided at the end of this report. GreenTech One LP is seeking a Specific Use Permit from the City to facilitate development of the Project. Submittal of a PDA,prepared by a skilled professional was requested by the City as part of the review process. This PDA was prepared in accordance with industry and local standards by registered professional engineers employed by Pacheco Koch. Pacheco Koch is a licensed engineering firm based in Dallas, Texas, that provides professional services in traffic engineering, transportation planning,parking analysis,and related fields. Purpose A PDA is an investigation of actual and/or published parking demand characteristics for a specific site with specific land use(s). The analysis is designed to take into consideration any site-specific factors that may affect parking demand. Therefore, the results presented in this analysis may not apply to other examples of the same land use. Parking demand is theoretically represented by local zoning ordinances. However, in many cases, these ordinances are overly-simplified and/or do not sufficiently reflect actual parking needs. The purpose of this PDA is to project the site parking demand at full occupancy and determine if the available parking supply is sufficient. Approval of any reduction is a subject to the approval process of the City of Allen. Project Description The Project consists of a single building containing approximately 36,636 gross square feet of building area. The building has two existing tenants representing 43%occupancy. The proposed tenant, Alliance Cheer, is an athletics facility for cheerleading and tumbling with three separate studios. The use would occupy 13,095 square feet. The remainder of the building, including an existing 7,771-SF vacancy,would be occupied by Office Showroom/Warehouse uses. A summary of the building occupancy and the associated base code parking requirements is provided in Table 1. Parking Demand Analysis Alliance Cheer at Tech Center One Page 1 Ordinance No. 3676-6-19, Page 6 EXHIBIT"B-1" AMENDED PARKING STUDY cont. Pacheco Koch February 7,2017 Table 1. Development Program Summary USE AMOUNT Suite 100 Office-6,749 SF Warehouse-1,806 SF Total-8,555 SF Suite TBD Office-5,828 SF Warehouse-1,943 SF Total-7,771 SF Suite 150 13,095 SF Suite 190 Office-5,802 SF Warehouse-1,413 SF Total-7,215 SF TOTAL 36,636 SF NOTE: The development program provided above is based upon the most current and complete information available at the time of this study publication. The site provides an off-street parking supply of 119 spaces. Code Parking Requirement The study site is currently zoned PD 3 - Light Industrial. The standard parking requirements are outlined in Article VII of the Land Development Code. A summary of the parking requirement per standard code rates is summarized in Table 2. Table 2. Base Code Parking Requirement LAND USE AMOUNT RATE DIRECT REQUIREMENT Office 18,379 SF 1 space per 300 GSF 61.3 Warehouse 5,162 SF 1 space per 2,000 GSF 2.6 Athletic Facility 13,095 SF See summary* 86.0* Total 36,636 SF I - 1 149,8 'A parking calculation-prepared by Owner, and approved by City—was based upon detailed use and occupancy data. A prior parking study for a similar athletic facility prepared by C&P Engineering,Ltd.and o letter explaining the operational characteristics of the proposed use were also provided by the Owner and are included in the Appendix. Pacheco Koch reviewed all Information provided and concludes that the parking requirement of 86 parking spaces is reasonable and is consistent with the findings of the previous study. NOTE: The cumulative parking requirement of 150 parking spaces for all uses exceeds the on-site parking supply of 119 spaces. However, the basis for the parking calculation is that the site will utilize shared parking as illustrated in the following section. Parking Demand Analysis Alliance Cheer at Tech Center One Page 2 Ordinance No. 3676-6-19, Page 7 EXHIBIT"B-1" AMENDED PARKING STUDY cont. Pacheco Koch February 7,2017 PARKING DEMAND ANALYSIS The parking demand for the two primary uses-office showroom/warehouse and athletic facility - are complementary in nature due to hours of operation and general operational characteristics. In other words,the peak parking demand for both primary uses do not coincide,so parking spaces can be used by both uses at different times of day. The following analysis summarizes the respective parking demand characteristics. Office ShowroomlWarehouse The typical office showroom/warehouse use, including the existing tenants at the subject site, has business hours from 8:00 AM to 5:00 PM on weekdays (closed on weekends). Based upon hourly occupancy data obtained from visitation statistics at similar businesses', the parking demand profile on a typical business day is graphically illustrated in Exhibit 1. Exhibit 1. Hourly Profile-Office Showroom/Warehouse Use ID0>, W 60`4 40`i zap ,/L Z As summarized in the graph, the peak parking demand for the office showroom/warehouse use occurs during the 11:00 AM hour. Cheerleading/Tumbling Athletic Facility The typical cheerleading/tumbling facility conducts group instruction from 4:30 PM- 10:00 PM on weekdays. Office hours and private instruction may begin as early as 8:00 AM. Most facilities also have additional business hours on weekends:however, the weekend analysis is not included in this study since the office showroom/warehouse businesses are typically closed during this time, and available parking is abundant. Based upon hourly occupancy data obtained from visitation statistics of similar businesses', the parking demand profile on a typical business day is graphically illustrated in Exhibit 2. ' Based upon hourly visitation data of individual businesses obtained by Google from aggregated and anonymized visitation data. Data available in Google Maps. Parking Demand Analysis Alliance Cheer at Tech Center One Page 3 Ordinance No. 3676-6-19, Page 8 EXHIBIT"B-1" AMENDED PARKING STUDY cont. February?,1017 Pacheco Koch Exhibit 2. Hourly Profile-Cheer/Tumbling Facility 100; 80% 60 40°r 20°x, As summarized in the graph, the peak parking demand for the cheerleading/tumbling facility use occurs during the 7:00 PM hour. Projected Site Parking Demand Using the respective City code requirements as the peak parking demand, the hourly parking demand for both land uses at full occupancy (i.e., no vacancies) were tabulated. As summarized graphically in Exhibit 3,the peak parking demands for the two uses are offset. The overall peak parking demands are anticipated to occur during the 11:00 AM hour and the 7:00 PM hour on weekdays. The parking demand during the overlapping hours of operation (generally 3:00-5:00 PM) are during the off-peak times for both uses and,therefore, do not cumulatively result in a peak condition. For all hours of a typical day, the parking supply of 119 spaces provided on site is anticipated to provide sufficient parking for the proposed land uses. Exhibit 3. Project Hourly Profile-Tech Center One At Full Occupancy 140 120 v 100 CL L v 80 V_ t 60 Y 40 O a 20 0 ■Office/Warehouse DAthletic Facility OAvailable Spaces Parking Demand Analysis Alliance Cheer at Tech Center One Page 4 Ordinance No. 3676-6-19, Page 9 EXMIT`B-1" AMENDED PARKING STUDY cont. February 7,1017 Pacheco Koch SUMMARY OF FINDINGS The following findings and recommendations are based upon buildout of the subject property in accordance with the development scenario outlined in the Project Description section of this report. FINDING: The office showroom/warehouse uses on site generally operate during the hours of 8:00 AM to 5:00 PM on weekdays. The peak parking demand for the uses typically occur during the late morning-noon period on weekdays. FINDING: The proposed cheerleading/tumbling athletic facility is expected to conduct group activity from 4:30 PM to 10:00 PM on weekdays. Office hours and private instruction may begin as early as 8:00 AM on weekdays. Additional hours of operation may also be provided on weekends; however,the office showroom/warehouse uses are expected to be closed on the weekends. The peak weekday parking demand for the athletic facility is expected to occur during the early evening hours,which does not coincide with the other uses on site. FINDING: Due to the complementary nature of the parking demands for the uses on the subject site, the parking supply of 119 spaces is expected to provide sufficient parking to accommodate the site at full occupancy. END OF MEMO Parking Demand Analysis Alliance Cheer at Tech Center One Page 5 Ordinance No. 3676-6-19, Page 10 TECH CENTER ONE at F,,,,hit THE TECH CENTER on GREENVILLE Zoning:PD 3 Light industrial Lot Size: 32 6967.12 Ac(117.420 sry 1N ai \ Soikling Area 37,127$F Lot=: 31.6% FAR. 0.315.1 Buy d,ng Height 27'-one story Par"Ra,d: 72 Packing PraYtl: 119 Accessible Padang Pravklad:As per TAS SUP REQUEST FOR ALLIANCE CHEER_LLC of Use:Gymnastics and Sports Training FacF:y ,� �•G,,,�,,,,�r+. //•' i r ��� \ r '/ /" /, 91. Tenant Space.13,095 SF ... p Parking Rata-1:100 Parking Req'd per Coos eGch Center One R / Perkier ProYd(pre-rale):a3 ��,' �d/ - /��' �e �j � /(//,Z;---//. e �A,yy Gu'dellnes for parking.crculation and pickup/drop off n111 be provided by Tenant to their clients upon enrollment am / 0 enforceo by Tenant as part of norma;operations. / b ON u/y / •� m \ ' / / � / /r ', Fel b •HSS�y,�� /�/k / // // // //� y 'r SUP SITE PLAN, I.�... C4h.xonNduata2xMn 8uwn,cwa .. caraNr,.r.w..ve.e ao,etnm,00smss.w sirt u.n,rx>fom -0cuKa � mrNr NaNr a rrn o»rs i ,eou wwn av,.sw.,m I .wn,x.ems MONK,: 0—k Nr.wasan _ mDN Ws�aol.Su"b ..�. � x,w,seee, VCN MYN NE62E. JaM tow EXHIBIT"B-1" AMENDED PARKING STUDY cont. J/Pacheco Koch APPENDIX Ordinance No.3676-6-19, Page 12 EXHIBIT"B-1" AMENDED PARKING STUDY cont. EXHIBIT`B" PARKING STUDY i ENVY CHEER CHEER AND TUMBLE SCHOOL PARKING STUDY PfWomd for Envy Cheer ! De m*w Z.2012 By C&P Engineering,Ch1. Demle cumm"P.PE / ONIKOU�MMMe �80�47 N�C&P Eriglrteering,L[d. 1101 wteway sma. stria 101 r�o�.r«�TSDeo i (97216442E00•T«o Ne�tntlm Na F-9115 Ordinance No.3143.2.13,Page 4 Ordinance No. 3676-6-19, Page 13 EXHMIT`B-1" AMENDED PARKING STUDY cont. EXHIBIT°B" PARKING STUDY(Continued) ENVY CHEER PARKING STUDY CITY OF ALLEN BACKGROUND DATA Ernry Geer is a Cheer and tumble schoa located in the City of Para at 961 Avenue N, Suite 200. They currently lease a Mai of approximately 5,000 s.f.;n advert suites(#MO and ft300)and use only 15 paftM spaces for staff and students. They offs,classes prinaNy after schooi and conduct a few morning classes on Sahr.-day and from 1:00 to 7:.30 on Sundays. Their peatt loss schedule occurs between 4:00 and 10:00 Monday trrough Thursday. On SaMiday and Sunday the viewing area is closed so students are dropped off and off-sheet parking does not occur. Envy Cheer's class schedule for 2012-2013 has bean attached to this report. Envy Cheer does not host competition meets or stow uses. WfM they are involved in such special events.Grey occur at renxAe bc2Wns such as the Dalas Convention Center, the Garland Everts Center,or the UNT Super Pt The other sullies within the Plano bu&ft are occupied by the Wowing businesses: Lets Party with 2:00 p.rr..-8:00 pm.hoes of operation; Track Studio Music Lessons with 3-OD p.m.to 9:00 pm.loin of operation; Reca-&V Sessions with 8:00 am.to 12:00 a.m.hours of oper*on; the Flooring Center with 8-0D a.m.b 8:00 p m.houas of operation: the Pool Sbck Company with 8:00 a.m.to 6:00 p.m.hours of operaton;and the Sem;-ConducW Company with 8:00 a.m.to 6:00 pin-hours 0.1 operation. Pepe 1 Ordinance No.3143-2-13,Page 5 Ordinance No. 3676-6-19, Page 14 EXHIBIT"B-1" AMENDED PARKING STUDY cont. t�IdtIT.$" PARKWG STUDY(Contin wO PURPOSE OF STUDY Envy Cheer is moving their tacftyy itom their press!, vocation in Plano b a new boon in Alen with appro*rtaWy 7,700 sl of space. The City o(Men's perking standards do not have a spedit-cM r and tumble sdwot'category As a resit the tam use that the City submpiently applied to Envy Cheer mmled in their need to provide over 70 parting spaces for their facility. This Is almost titre times the mrnber of spaces that Erry Ctneer aatentty uses for their operabon In Piano. The City of AlesYs Land Deveiopment Code in Section 7.04.1'Vehicle Parking'provides ibr the foRawi g. The Diredorand Dkoctor of Ertgis)ering may josri ly grant a modification b off-street parking regrriremenfa when necessary for the etldent operation of the subject use. Such a modification in parking spaces shall be justified through the development of a paftg sb*Wepared by a professional er9neerarfrarrsportatiots plarrserwhich demons Mies need,reviews y standards.and proposes a mod taim that ' will nil result in a panting del fncy. CSP was engaged to conduct a par"study to delersrtirse and quantify the actual number of dl-street trdrtaing spaces o enty required by its bcffly in Marv. Page 7 Ordinance No.3143-2-13.Page 6 Ordinance No. 3676-6-19, Page 15 EXHMIT`B-1" AMENDED PARKING STUDY cont. EXHi1;1T`B" PARKING STUDY(Continued) STUDY METHODOLOGY To detefmtne the aMal number of off-street pa"spaces currently required by Envy Cheers Pkm favi ty,we developed the following five step process. 1. Engage a quaified traffic data wkdon compayt. 2. IOentiiy the time pend dung which to collect parkng data 3. Delermne the data to collect 4. A WVW and evaivale the collected data to der m**the peals number of pig sPaws used by Envy Cheer and research ndustry stanclards for possible parking rates kx tits type of taakty. 5. Prepare a report to summame the overall parking study process and present the off-sheet parking findings. COMIC INIG THE PAFWJNG STUDY The fo mvV paragraphs lunrnartm and desatbe the five steps listed in the Stady Methodology in the previous section of 1his report TRAFFIC DATA COLLECTION COMPANY hlehomrnt,located In Phm was engaged to oohed the pa*M data. They have been co lectng traffics data in the DFW area for over 3C years. IDENTIFY THE PERIOD Based on the tours a:operation during wNch classes were offered we chose the Wowing Wm pend for our data coM cbw:4:00-7:00 p.m.durahg a Monday t cuugh Thursday weekday. Page 3 Ordinance No.3143-2.13,Page 7 Ordinance No. 3676-6-19, Page 16 EXMIT`B-1" AMENDED PARKING STUDY cont. EXHIBTT"B" PARKING STUDY(Continued) DETERMNE THE DATA TO COLLECT Data collectors were poshoned both in the from of the btatfi*and in the back of the btaditg fo observe vehicles wMi passengers that eMered and exfied the Envy Cheer site. Data was coleMd relating W`parked'vehicles. We collected data perUNft to the mimber of vehicles that parked in paitdng spaces at Envy Cheer's site and the number of vehicles that lett parking spaces at Envy Che&es sites_We defined these vetudes ars those whose occupants all lett their vehicles and entered the Envy Chew site and those whose occupy all exited*m the Envy Cheer site and entered their vehicles. The'parked'vehicles data was recorded by the exact time Mail a vehicle wtIw parted in a parking space or exited trvm a paftV space between 4:00 and 7:00 on Tuesday August 21. We also coCected data reiatsrg th`drop oft'students. We defined these veludes as those vehicles that pu0ed up to the Envy Cheer fact*and either dropped off or pureed up a student They did not park. This data was col acted In five rnirw&ktte'vals between 4:00 and 7:00 p.m.on Tuesday August 21. The field data sheets shoving the achy dada colected have been attached to this wport- ANALYZE AND EVALUATE THE PARKING DA�9 Table 1 summar¢es the parking data that was cof+ecied by Metocount. TABLE t PARKING DATA TIME I PARKi"PVELQEP DROP OFF VEHICLES PERIOD ARRIVE DROP OFF P"UP 4:00-4:30 4 5 C 4:30-5:00 10 0 4 0 5:00-5:30 2 1 1 1 5:30-6:00 2 7 1 0 6:00-6:30 1 2 1 0 1 i 6:30-7:00 6 13 5 0 TOTAL 25 26� i3 1 Page 4 Ordinance No.3143-2-13.Page 8 Ordinance No. 3676-6-19. Page 17 EXHIBIT`B-1" AMENDED PARKING STUDY cont. EXEIIBIT`D" PARNING STUDY(Continued) During any one 30 n nhde Period of the parking data the maximum number at customer p2!kng spaces needed was 10 which ocnured during the 4'30-5:00 time period. During ar other 30 minute tette periods.we vehicies unparked than parked. During that same time period of 4:30-5:00, four veftes were recorded dropping off students_ Potentia0y these four vehicles could have chosen to park. If we combine the Piked and drop off vehicles during lift 30 mirnAe Peak Period, We get a Potential maximum curatonier parluing need at the existing Placa site of 14 spaces. The Owner indicated a need fa two staff parking spaces which results in a maximum Parking need at the exising Piano sire of 16 spaces. This correlates wet with the Owners original shatamit of using 15 spaces for his carrent operations. The new VIs in Allen will i cream the available spars by approximatety 50%• By applying Nus factor to the Pias maximum parking need quantified in the preceding Pala~we obtain a maximum parking need for the neer Allen site of 24 spaces- We researched available Perking data as colvcted and doamvu ted by the Institute of Transportation Engin eers,the Eno R indation.and the Urban Land Institute_ Data for businesses such as a cfheer and kmtAe school or other gymnastics,type facilities were not available. The closest possibly similar Wind uses were heallh and athletic dubs_ PREPARE REPORT C&P has prepared this MW to doc urnent the process that we used to determine the aduW number of off-street parking spaces that the Envy Cheer facility in Plana actn9y needs for ft customers. Our study has determined M during a typical peals Period the Potential rxanber of off- street &street spaa3s actually needed In Pham was 16. Wath an approximate 50%increase in the square footage at the new site in Alen we recommend MW 24 parking spaces be used as the number of off-street spaces that the new Envy Cheer facility in Allen be requited to provide. CLOSING We have appred ged the oppoftundy to assist the owners of the Envy Cheer facility in the preparation of tins Parking study for your new site:n Allen. Please do not hesitate to contact our office should you have any questions or comments concerning this report. Page 5 Ordinance No.3143-2.13,Page 9 Ordinance No. 3676-6-19, Page 18 Sit rl y Nsonetay "V,aasala�r s�` sy slsday 3Stuld>3yr lT�lcs 7•!R 401*5 4.1" 9301290 Jr 2 ASA Chaar ASA Lamgank Starding 9145 clan Tumble 1-2 SR4 Tumble 34 2304015 4A$-S:AS 4AS-S:43 44" irs Tumble 12 Tumbie 1-2 Tunibka 2-3 SjO4W Ti"We 1-2 �J p TUmbla 2-3 Turabla 2-3 Z z a Sts SO6Je00 Rat ASA Cowboys 7s�C Rae C7 514 5;J10]�4 � x e 3 ';S LAS TU rnme 23 ?R 3 night Class Tumble 3.4 a �IAIS 2:34!;312 N a>as-i-..� Tumbir 34 SRS Z SR 4 fl fight class Right class 1Umbla4-3 n ►+ 5 -3 TUntme 4-sCD C7 p � igrsdl�ig,Tkaddstk�s � r, '•Last meek of the morith Is BRING A FRIEND fo TUMBLE "2"d FRIDAY of evamir month Is FUPPIN FRIDAY NIGHT 6:348:30$10.00 7' 1-2 Tumbiina:A lot of focus Is put on the bask of tumbling:le Round-offs,handstands,and Introductloninto back handspring. 2d Tumbling:Round off handspringserles,trot walk over th rougN back handspring step-outs,and standing back handspring series. 24 nnbtifsc:Round off bock handspring tuck,spedalty pssses through atuck standing back handspring tucK and sbndingtutb are the sal pohtofthis class.Aswell asIntroducing the students Into proper layout techniques. 43 TUmblim:Layouts standlng to layout,fulls,standing fulls,and standing to fulls are the main sklils worked on In this class. ••Students with a standing tuck are reoommendedfor this class onhy.•' Iifgft Class:$20.00 StandinS BHS Classes:$45.00 Registration Fee:$45.00 Tun*kng Classes:$65.00 Standing Toch Classes:$45.00 EXIMIT`B-1" AMENDED PARKING STUDY cont. EDIT IS" PARKING YfUDY(Continued) Lin { c I f• o Ii _ t � _ _ J� 1 Sol _ k r i 60 ; . er 17 Ordinance No.3143-2.13,Page 11 Ordinance No.3676-6-19, Page 20 EXHMIT`B-1" AMENDED PARKING STUDY cont. EXHIBIT"n" PARIONG STUDY(Continued) Fop Ig Pic -a p e �►�s- - '. 1 1 Id d 1 ('61493 4f 11 1 �- 1 4-40 _ � I ! LL.I . L._...�, _. �s. IJII F1 - LJAJIA LJIIJ Ordinance No.3143.2-13.Page 12 Ordinance No. 3676-6-19, Page 21 EXHIBIT"B-1" AMENDED PARKING STUDY cont. JaRyCo Development,LLC �� �O 780 N.Watters Rd.,Suite 120 Allen,TX 75013 Tel:(214)495-8581 D E V E L O P M E N T www.jaryco.com VIA E-MAIL/HAND DELIVERY February 1,2017 Bo Bass Madhuri Mohan City of Allen 305 Century Parkway Allen,TX 75013 RE: Alliance Cheer SUP Dear Bo and Madhuri: I know we are meeting in the morning but thought it might be helpful to provide the information below for review prior to our meeting. We are always as concerned,possibly more so,than the city,with any potential parking issues created by a tenant.These types of problems only create challenges with our other tenants and ultimately lower the value of our asset.Sixteen years ago on our first Allen project,The Atrium at 1333 McDermott,we had a tenant that grew very quickly and created a parking problem.We resolved the problem but the time and effort required to do so made Cindy and I realize that we never wanted to re-live that experience.We modified our leases whereby any creation of such problems is a default under the lease that is required to be corrected.The default does not terminate the lease,it simply required the tenant change their processes to avoid causing the problem while they continue to pay rent.Our lease with Alliance Cheer contains these default provisions.In addition,we maintain a parking spreadsheet on all JaRyCo properties that tracks code required,lease required and anticipated actual parking use by each tenant so that we make sure we do not create a problem during the leasing of a project. Special type uses always need to be analyzed carefully.We shared the same concern as the city staff when we were first approached by Alliance Cheer.Given the limited use types in the typical ordinance for parking counts, a detailed review of the actual tenant operations is the best way to determine tenant demand and usage requirements.We did that with Alliance Cheer and became very comfortable with the anticipated parking needs. Per the parking breakdown previously provided to staff and attached,using the ordinance requirements, a need of 86 spaces would be required.In reviewing the actual business model for Alliance Cheer,the anticipated parking demand will be much less. Our primary concern was the peak activity times(worst case scenario)for the facility.There are no competitions at this facility,only training and practice activities.Nearly all of Alliance Cheer's clients will be school age children and most do not drive,therefore they are brought to the facility by their parents.Historically,less than half of the parents stay to watch practice(especially the cheer practices which last 2-1/2 hours)and simply drop off the children,go run errands or go back home and return an hour later to pick up their child.The maximum size cheer team is 20 individuals.With three training floors,that would result in a total of 60 clients at any one time.With half of the parents staying,that would create a need for 30 parking spaces,well less than the 43 allotted to this facility even during daytime hours. Ordinance No.3676-6-19, Page 22 EXHIBIT"B-1" AMENDED PARKING STUDY cont. February 1,2017 Page 2 of 2 The anticipated weeknight scheduling for the facility is as follows: Tumbling Floor: Class Times of 4:30 pm—5:20 pm,5:30 pm—6:20 pm,6:30 pm—7:20 pm,7:30 pm—8:20 pm and 8:30 pm—9:20 pm. Cheer Floor A: Cheer Team Practice at 6:00 pm— 8:30 pm Cheer Floor B: Cheer Team Practice at 7:00 pm—9:30 pm The Saturday and Sunday schedules are only cheer team practices that will only be using two of the floors at any one time.As you can see,the session times are staggered to avoid a huge"shift change"parking requirement.In addition,typically only one floor will be in use while our other typical 8:00 am—5:00 pm tenants are at the property.With a total of 119 parking spaces at this property,we will have more than enough parking for the peak periods of use. The second concern was the off-peak usage during the day when our other tenants are present.Based on a pro- rata distribution of parking based on tenant square footage,36%of the parking,or 43 spaces would be allocated to Alliance Cheer during the day.There would be no public scheduled activities at the facility on a regular basis during the non-peak times.The activities during these times would be staff activities,individual and small group extra training with a coach or perhaps a cheer team(but only the ones that are old enough to drive during the day)that would practice.The maximum use if a cheer team did practice would be 20 clients and even if each of them drove separately,that team and a few staff people would only use slightly over half of the allocated parking.Again,none of these activities are open to the public. Thank you for sending the parking study prepared in 2012 by C&P Engineering for Envy Cheer.I reviewed and found that the basis of that study matches nearly identically the proposed operations of Alliance Cheer. That study recommended a total parking need for the 7,700 sf facility(two training floors)to be 24 spaces. In comparing those recommendations with the size of Alliance Cheer,41 parking spaces are needed if calculated on a square footage basis or 36 parking spaces are needed if calculated on the number of training floors.These parking space requirements can be met even in our daytime conditions(we are providing 43 spaces)and are less than one third of our 119 total parking spaces at the property. As we have discussed,there have been no parking issues at Envy Cheer that the City is aware of.This likely validates the parking study prepared.When comparing the properties,the 21 Prestige Circle location has a total parking count on site of 62 spaces or a 1.2 per thousand parking ratio to the total building size.Tech Center One provides a 3.2 per thousand parking ratio.The parking provided for Envy Cheer ranges from 2.78—3.2 per thousand depending if you use the space square footage on their website or in their SUP.We are providing parking for Alliance Cheer at a ratio of 3.3 per thousand. If we ever have a parking problem due to Alliance Cheer,I will be first to get the Landlord call from an angry tenant.I don't want that call and I certainly will never let the situation escalate to where the city needs to get involved. I look forward to finding a way to present this project to the City Council and obtaining approval of our SUP so that we can proceed with bringing this tenant and their services to the citizens of Allen. Sincerely, Bruce R.Heller President Ordinance No. 3676-6-19, Page 23 EXHMIT`B-1" AMENDED PARKING STUDY cont. Tech Center One Alliance Cheer LLC Code Parking Code Parking use Size(sf) Ratio Required Training 7644 100 77 Office/Restrooms/Storage 1014 300 4 Reception/Pro-Shop 843 200 5 Parking already covered with participant in training Parent Waiting 496 area above Open space between training floors and other areas,no occupants to drive Circulation 3098 parking count Total Parking Required based on space breakdown 86 Notes: 1. Full usage of each training floor consists of a team of 20 participants.Based on three training floors,a total of 60 parking spaces would be required intead of the 77 noted above. 2. Historical operating data indicates that less than half of the parents remaing to watch practice which would indicate a total of 30 parking spaces needed per session for participant parking. Ordinance No. 3676-6-19, Page 24 EXHIBIT"B-1" AMENDED PARKING STUDY cont. Tech Center One Alliance Cheer LLC Expansion Code Parking Code Parking Anticipated Use Size(sf) Ratio Required Parking Required Training 11350 100 114 44 Office/Restroom s 1474 300 5 5 Storage 190 2000 1 0 Reception/Pro-Shop 585 200 3 3 Parking already Parking already covered with covered with participant in training participant in training Parent Waiting 1932 area above area above Open space between Open space between training floors and training floors and other areas,no other areas,no occupants to drive occupants to drive Circulation 5335 parking count parking count Total 20866 Total Parking Required based on space breakdown 123 52 Notes: 1. With the five training floors,three will be dedicated to teams(16 people per team)and two will be designated for training(20 people per floor). 2. Historical operating data indicates that less than half of the parents remaing to watch practice which would indicate a total of 44 parking spaces needed per session for participant parking. 3. Tenant operational hours are limited per the lease to evening and weekend hours which does not interfere with the normal business hours of other tenants. Ordinance No. 3676-6-19, Page 25